Integrated Component Configuration
Devices > Integrated Component Configuration
Integrated Component Configuration

The Integrated Component dialog can handle any type of panel components (partition, zone...etc) under any type of panel (intrusion, temperature control,...etc).

1 - From the Devices  toolbar, select the Integrated Component button.

2 - Select the Component from the drop-down list.

Closed Note...

3 - Select the Component type .

4 - Click on the Configuration Form  button to display the DSC Power Series dialog.

5 - For a User component type, enter the User access code. This code is a PIN number used for arming or disarming a partition.

6 - For a Simplex panel, select proper values to define the fire panel device point. Once the device is granted an address (manually or automatically from IDNet import), the user will not be allowed to change it unless the point is deleted and another one is created.

7 - For a Virtual Zone:

The purpose of that feature is to create "virtual" zones in an alarm panel that will receive commands from groups of selected input, doors and other events of a gateway. These commands are then transmitted from the panel to a central station.

 

ClosedNote...
ClosedNote...

•  Select a Component type from the drop-down list (Door, Input or Event).

•  For an Event component type, select an event (please refer to the following table for a list of events based on the selected component type).

Events sent to the virtual zone
ComponentEntraPass EventReport AlarmReport TroubleReport Tamper
Input

Input in alarm / Input restored or in normal condition

X  
Input in trouble/ Input in trouble restored X 
Input tamper in alarm / Input tamper restored  X
DoorDoor forced open / Door forced open RestoredX  
Door open too long / Door open too long restore X 
Door lock device failure / door lock device failure restored X 
DuressDuress featureX  
ControllersController AC power failed / Controller AC power restored X 
Tamper switch in alarm / Tamper switch restored  X
Controller Auxiliary power failure / Controller Auxiliary power restored X 
Controller reader power failure / Controller reader power restored X 
Controller battery power failure / Controller battery power restored X 
Controller module communication failure /Controller module communication restore X 
Controller DC power failed / Controller DC power restored X 
Controller lock power failed / Controller lock power restored X 
Controller power trouble (KT-1) X 
Access DeniedAccess denied - Bad card status X 
Access denied - Card lost or stolen  X
Access denied - Card expiredX  

•  For a Door or Input component type, indicate the component source (controller)

•  Check the appropriate Component action to be reported for the virtual zone and click OK.

8 - If the Video feature is enabled, the Video view field appears (for zones and partitions only). If this is the case, select the Video view in which you want the defined component to appear. For details on defining video views, see Video Views Definition .

9 - From the Graphic  list, you may select the graphic to which the application is assigned, if applicable (for zones and partitions only). For details on defining graphics, see Graphics Definition .

Closed Note...

10 - Click Save .

See Manual Operations on Integrated Panels to complete the configuration.